Fld series, direct read rotameters browse online, omega. King instrument 7330 series rotameter rotameters instrumart. It is particularly suitable for metering carrier gases in chromatography, indicating and controlling gases in manufacturing processes, liquid and gas measurement in laboratories, pilot plants, flow and level indicating, etc. The different designs of the flowmeters have a variety of applications. Rotameters are safe, accurate and widely used processing.
The float response to flowrate changes is linear, and a 10to1 flow range or turndown is standard. Glass tube rotameter eureka variable area flow meters rotameters work on the principle of variable area. Steps to installing a rotameter industrial process control. Due to this flexible and modular system it can be equipped with additional features and various materials suited for all kind of applications. Knowing an applications required flow rate is necessary when specifying a rotameter. The float moves freely up and down in the tapered borosilicate glass tube with fluid flow from bottom to top. Its based on simple and easytounderstand flow measuring principle but is versatile in the types of fluid it can measure and site conditions, under which it. The flow metering tube is transparent giving you full insight into the process and position of the float a scale on the outside of the tube indicates the true flow rate. Rotameter and also at the inlet and outlet of the orifice assembly for bypass type rotameter. Rotameter is a variable area type of flow meter used to measure the flow rate of liquids and gases. Venturimeter% herschel1898mentionedthataventuri meter constrictsthe flow insome fashion, and pressure sensors measure. Kings focus is on using proven technology and longstanding methods to build the most accurate, versatile, and economical rotameters possible. Rotameters do not offer high accuracy and a typical accuracy of 2 to 3% fsd is probably the best that can be achieved. The shortstroke rotameter ramc allows the measurement of high flow rates using a relative short metering tube.
Low flow meters are available with stainless steel frame type construction. The variable area flowmeter is one of the oldest and mature principles in flow measurement with its simple design. It is particularly suitable for metering carrier gases in chromatography, indicating and controlling gases in manufacturing processes, liquid and gas measurement in laboratories and pilot plants. The flow rate can be read with great accuracy on the external lcd which, together with the magnetic unit, is held in a sealed, mouldcast aluminium case. The rotameter consists of a plastic, metal or glass tube and float. Because of the prevailing physical relationships, the measurement technique is dependent on the density, viscosity and temperature of the medium. Omega fl50000a series flowmeters feature a rugged, onepiece acrylic body, stainless steel internal parts, rear inlet and outlet ports for panel mounting, and excellent accuracy. On the rear of the ramc are two cable glands for round cables with a diameter of 6 to 9 mm not for exdtype option. The float takes up a position where buoyancy forces and the float weight are balanced in proportion to flow rate. The rotameter is popular because it has a linear scale, a relatively long measurement range, and low pressure drop.
Parkers expanded pseries rotameter line is an allnew range of flow meters that provides significantly greater application versatility for industrial applications. Flow meters rotameter variable area flowmeter rotameter variable area flowmeter. They have 6inch 150 mm scales and provide outstanding 2% f. Fl3802c, 150 mm rotameter, nonrising stem valve aluminum unit, with carboloy float, range of 1222 ccmin air, 33. The higher the flow the higher the float is pushed up the inside of the tube. Specialty rotameters bulls eye sight flow indicator series 10e1400 used in many industries to monitor and indicate ow through. Half unions couple the meter body to the connectors at each end of the flow meter, facilitating both installation and maintenance. Oriflowrator meter is an all stainless steel variablearea. Results 1 9 of 9 free shipping on many items across the worlds largest range of dwyer variable area flow meter rotameter flow meters. Rotameter applications extend across industries because it was and still is an economical way of measuring very low to high flow rates. Sep 19, 2011 the rotameter consists of a vertically oriented glass or plastic tube with a larger end at the top, and a metering float which is free to move within the tube. Fluid flow causes the float to rise in the tube as the upward pressure differential and buoyancy of the fluid overcome the effect of gravity.
A flow meter is a device used to measur e the flow rate o r quantity o f a gas or liquid moving through a pipe. The combination of a cone, a float, a scale and a process connection build up a rotameter. Maxiflotm metal tube rotameter 1 overview maxiflotm km series metal tube rotameters are rugged, versatile and accurate variable area va flow meter offering 2. Apr 30, 2015 a rotameter, also known as a variable area flowmeter, is a device that measures the flow rate of liquid or gas in a closed tube. Rotametersvariable area flow meters tech info from coleparmer. A rotameter is a device that measures the volumetric flow rate of fluid in a closed tube it belongs to a class of meters called variable area meters, which measure flow rate by allowing the crosssectional area the fluid travels through to vary, causing a measurable effect. Unused glands must be closed with a blind plug m16x1. Bidder to also specify any other requirements as per his recommendations. Sinceviscosityandradiusoffluidisconstant,withthevelocityincrease s,the shearstressoffluidwouldinc reaseaswell,whichwillcauseenergyloss. See below pdf file for example of calibrating a 5 lpm rotameter with compass for molbox calibration software and a molboxmolbloc flow calibration system. Variable area flowmeter ariable area flowmeter rotameter. In the 1990s, yokogawa strengthened its focus on flow meters through cooperation with and the eventual acquisition of the german flow meter manufacturer rota. Flow measurement applications ar e very diverse and each.
The rotameter is an industrial flowmeter used to measure the flowrate of liquids and gases. Rotameters with 150 mm flowtubes polycarbonate shield acts as a magnifier to insure high accuracy reading with less eye fatigue. Flow measurement with orifice,venturi and rotameter engi tube. Rotameter flow meters houston, tx king instruments. The rotameter should be used only for the fluid or gas for which it is designed. Krohne is a worldleading manufacturer and supplier of solutions in industrial process instrumentation. Also see quickstart guides here, molboxmolbloc flow calibration system quickstart guides. Stainlessbody 200 f low cost, all metal meter for flow 5% vertical 1500 psi air 7 indication and flow switching of 12, 1, 112, 2 in. These economical kits are ideal for laboratories, schools or processes that use multiple gases.
Fl2500 series direct read acrylic rotameter kits omega. It is a closely held company owned and operated by erik and lars rosaen. Customers have been asked why they select rotameters. Pvc fittings are standard to the king instrument 7330 series rotameter. There are many instruments used in flow measurements such as. With a 1 fnpt connection, this line has a liquid flow range of 0. If the mechanical, thermal or chemical resistance properties of the glass meter tube are not adequate for certain applications, metal meter tubes can be utilized. A rotameter is a device that measures the flow rate of liquid or gas in a closed tube. It is a longtime industry standard for a wide range of liquids and gases, ideal for applications requiring visual flow measurement, including liquid measurement for leak detection. A rotameter flow meter is used to measure the flowrate of liquids and gases. The float position, which is a measure of the instantaneous flowrate, is indicated external to the metal meter tube by a. In the present study design and analysis of rotameter performance is done using ansys fluent 14 software. Qingtianweiye is rotameter flow meter supplier,we can provide sizes from dn15dn150,can measure medium 80160.
Rotameter calibration example in compass for flow, 5 lpm. It is a stainless steel armoured construction for the safe measurement of a variety of liquids, gas and steam. Fr6000 series f024m f025m f026m f092m f093m a009 a010 variable area flow meter rotameters plastic variable area flow meters shorate series 1250a 1255a 50g 55g 58. Mar 15, 2020 dwyer variable area flow meter rotameter flow meters for sale ebay. Since this measuring method is purely mechanic, it as simple as it is reliable. Theory and calibration procedures for the use of a rotameter. The computeraided design cad files and all associated content posted to this website are created, uploaded, managed and owned by third party users. Mp stainless steel wetted parts high pressure and temperature resistance withstands aggressive media atex version ii 2gd c tx as option. As a result, yokogawa gained access to 100 years of flow meter expertise and completed its flow meter portfolio by adding the rotameter variable area and rotamass coriolis product lines. Rotameter it belongs to a class of meters called variable area meters, which measure flow rate by allowing the crosssectional area the fluid travels through, to vary, causing a measurable effect.
Aug 07, 2019 dwyer ratemaster series rm flowmeter, 10. Flow capacities ranges for the flowmeters described in this catalog are given for air at standard conditions 14. The goal is to select a meter where the normal operating flow is in 60% to 80% of the meter s range, because variable area meters are more accurate in the upper part of its range. It is compatible with a wide range of liquids or gases. The stainless steel float guide helps reduce float oscillation and improve overall performance. The flow in a floating element flow meter rotameter was studied with laser doppler anemometry lda and computational fluid dynamics cfd. Additionally, the meter must also handle the minimum and maximum flows. Meters can be supplied with flow controllers and plastic bezels for flush mounting not available with 1 12inch scale purgemeter. Slowly open the valve until the float is at the desired flow rate. Shipped completely assembled, flow meters include standard mounting fittings in a. The rotameter is estimated to be in its second century of serving customers and their many and various flow flow meter applications. The tmd series flowmeters for direct readings are instant flow meters with magnetic coupling of the measuring element.
The variablearea type flowmeter, or rotameter, is one of the most economical and reliable of flow measurement instruments. Aug 11, 2019 dwyer ratemaster series rm flowmeter, 10. These fittings are rated for a maximum temperature of f 54c and maximum pressure of 150 psig for sizes 4172w and 125 psig for sizes 90103w. In the case of omega laboratory rotameters, far greater flexability is possible through the use of. All the measurement tubes in this series of variable area flowmeters are made of either glass or plastic.
The float position, which is a measure of the instantaneous flowrate, is indicated external to the metal meter tube by a transmission system see fig. This specialization has allowed king to be a customerfocused provider of one of the most comprehensive lines of standard and specialized variable area flowmeters anywhere in the world today. Rotameter working principle animation instrumentationtools. The average velocity of flow through the rotameter is given by q m a m where q m is the volumetric flow rate through the meter and a m is the annular area between the inside circumference of the tube at the float position.
For the love of physics walter lewin may 16, 2011 duration. The fluids temperature, pressure and specific gravity all impact gas flow measurements. Each kit includes seven interchangeable direct read scales for air, water, argon, co 2, helium, nitrogen and oxygen. Feb 14, 2017 variable area flowmeters rota meter droplet flow meters are manufactured under totally automation environment and with state of the art high precision machines. Millions of users download 3d and 2d cad files everyday. In various configurations flow meters can be designed to withstand high pressures, corrosive fluids, high temperatures, and is completely independent of factors influencing electronic meters. Scale range size inch d mm sk scale range gpm 1 32 10 0. It measures flow rate by allowing the crosssectional area the fluid travels through, to vary, causing a measurable effect. Rotameters simple to use flowquip flow measurement. Rotameter calibration example in compass for molbox, 5 lpm. Fl50000 series, panel mount flowmeters browse online, omega. Purge meters a major type of rotameter variable flow meter that is used in purge systems. The medium is visible and the flow value of the gas or liquid can be read directly off the scale at the height of the float.
Flow rate can then be read by observing where the top edge of the float meets the graduated scale marked on the outside of the tube. Exact results can be expected only if the characteristics of the medium remain constant. Flow meter manuals, drawings, certifications, and other. The different sensors include rotamter, inline, ultrasonic, orifice plate, totalizing meters, variable area, venturi, or with switch output. The fl2500 series direct read rotometer kits offer versatility at a low cost. How to install a rotameter a rotameter, also known as a variable area flowmeter, is a device that measures the flow rate of liquid or gas in a closed tube. Glass and metal tube purgemeters for low flow applications meters up to dn150 6 optional electronics. Whether its dust, moisture, temperature extremes or washdown requirements, the slamf series elastomersealed thermal mass flow controllers and meters deliver the precise accuracy and longterm stability of our proven sla5800 family of meters and controllers.
It is a variable area meter which works on the principle of upthurst force exerted by fluid and force of gravity. For simple and costeffective flow measurement of gases or liquids without auxiliary power. Rotameters variable area flow meters yokogawa america. Station 4 compass for flow setup combined, 5 alm rotameter. Pvdf fittings are available as an option to the king instrument 7330 series rotameter. Variable area basic fundamentals flowmeter and descriptions. Dwyer offers different types of dial flowmeters for various applications. Validation of cfd methodology is done by using flow through pipe in a turbulent flow. Typically low capacity systems that are used for liquid level control, density and pressure controls. See below pdf file to setup and calibrate a 5 liter per minute rotameter variable area flow meter with compass for flow calibration software. Each cad and any associated text, image or data is in no way sponsored by or affiliated with any company, organization or realworld item, product, or good it may purport to portray. In the case of omega laboratory rotameters, far greater flexability is possible through the use of correlation equations.
Tube flow meter is designed to withstand rough conditions. The different sensors include dial, inline, ultrasonic, orifice plate, totalizing meters, variable area, venturi, or with switch output. They can be produced in version with pressure compensated or not compensated, and manufactured both with single or twin flow tubes in order to allow a double and independent gas supply using a single gas source. This familyowned business started out making variable flow switches for the automotive industry and today services concrete, defense, chemical processing, mining, wastewater, energy, electronics, laboratories, medical, and many other industries. Designed for direct read flow rates, the fld series rotameter is a precision instrument. The measurement of water flow rate is an important topic in the study of fluid dynamics.
272 914 1414 9 497 867 1200 28 1220 1355 563 1497 516 893 53 1192 426 634 161 1131 813 267 300 631 65 1387 555 4 1443 337 321 823 857 892 547 999 959 890 1176 135 127 1254 490 1333 1385 1410 773 543